Product Details

$175.00

X-Ray Grid for Sharper, Clearer Radiographs

An X-Ray Grid sits between the patient and the image receptor and traps the scattered radiation that fogs a radiograph, so the image comes back sharper and higher in contrast. Scatter is the biggest reason a film or a DR image looks flat or hazy, and a grid is the standard fix. This grid comes in a range of sizes, grid ratios, line counts, and focal distances, so you can match it to the room, the tube distance, and the exam. Pick the configuration that fits your setup, and the grid drops into a cassette, a DR panel protector, or an encasement.

Info Product

Category:
Get a Quote

Description

Specifications

Product Type Anti-scatter X-ray grid
Sizes Several, from about 11 x 13 to 18 x 18 inches
Grid Ratios 4:1, 6:1, 8:1, 10:1, 12:1
Lines Per Inch 85, 103, 150, 178
Focal Range 34 to 44 in and 40 to 72 in (by option)
Grid Type Linear and criss-cross
Made In South Korea

How to Choose an X-Ray Grid

The right grid depends on three choices. Grid ratio sets how aggressively the grid cleans up scatter: a higher ratio, like 10:1 or 12:1, traps more scatter and sharpens contrast, but it needs tighter alignment and a bit more dose, while a lower ratio, like 6:1 or 8:1, is more forgiving to position. Lines per inch, or grid frequency, runs from about 85 to 178; a finer line count hides the grid lines better, which matters for digital work.

Focal distance has to match your tube to image distance, so a grid rated 34 to 44 inches suits table work, and one rated 40 to 72 inches suits a chest or a longer distance. As a rough guide, a skull or a general study runs well at 103 lines and a 10:1 ratio at 36 to 40 inches, a chest moves to a 10:1 or 12:1 at 60 to 72 inches, and a CR or DR chest often uses a parallel grid at 150 or 178 lines.

Features

  • Traps scatter radiation, so the radiograph comes back sharper and higher in contrast.
  • Grid ratios from 4:1 to 12:1, so you can match cleanup to the exam and the dose.
  • Line counts from 85 to 178 per inch, including fine counts that hide grid lines on digital work.
  • Focal ranges for table work and for longer chest distances.
  • Sizes from about 11 by 13 to 18 by 18 inches to fit common cassettes and DR panels.
  • Drops into a cassette, a DR panel protector, or a grid encasement.

Frequently Asked Questions

What does an X-ray grid do?

It traps the scattered radiation that fogs a radiograph, so the image comes back sharper and higher in contrast. The grid sits between the patient and the image receptor.

Which grid ratio should I use?

A higher ratio, like 10:1 or 12:1, cleans up more scatter and sharpens contrast, but it needs tighter alignment. A lower ratio, like 6:1 or 8:1, is more forgiving of position. Match the ratio to the exam and the dose.

How do I pick the focal distance?

Match it to your tube to image distance. A grid rated 34 to 44 inches suits table work, and one rated 40 to 72 inches suits a chest or a longer distance.

Does it work with a DR panel?

Yes. The grid drops into a cassette, a DR panel protector, or a grid encasement. For weight-bearing and equine work, the weight-bearing tunnel protects the panel underneath.